There are generally six ways to prevent the battery from being overcharged: 1. Peak voltage control: Determine the end point of charging by detecting the peak voltage of the battery; 2. dT/dt control: Determine the end point of charging by detecting the peak temperature change rate of the battery; 3. T control: When the battery is fully charged, the difference between temperature and ambient temperature will be the maximum; 4. -V control: When the battery is fully charged to reach a peak voltage, the voltage will drop to a certain value. 5. Timing control: Control the charging end point by setting a certain charging time, generally set the time required to charge 130% of the nominal capacity to control; 6. TCO Control: Considering the safety and characteristics of the battery should avoid high temperature (except for high temperature batteries) charging, so the battery should stop charging when the battery temperature rises to 60 OC. Pe800 Embroidery Machine,Embroidery Machine For Shirts,Professional Embroidery Machine,Home Embroidery Machine Ningbo World Wide Electric techonology CO.,Ltd , https://www.ningbomachine.com
Control method for preventing battery overcharge
In order to prevent the battery from overcharging, it is necessary to control the charging end point. When the battery is full, some special information can be used to judge whether the charging reaches the end point.